| af-01 | Lighting circuit faults | regulator step and output current, insulation resistance, vault alarms | safety, compliance: Part 139 lighting must work. Maintenance follows AC 150/5340-26C. SFB: 8 runway plan points. | yes (The ALCMS and its regulators; closed network (AC 150/5345-56B)) | A one-way export agreed with the ALCMS maker | airfield.lighting.circuit_fault (fault)<br>airfield.lighting.step_changed (state) | P1 | 1 | S-CAT, FAA-5340-26C, FAA-5345-56B | V |
| af-02 | Individual lamp outages | lamps out per circuit | safety, compliance: The regulator cannot see single lamps. SFB: Mission already drafted in MissionSight. | no (lamp-level monitoring is an add-on (ADB SAFEGATE LINC 360)) | The nightly drone pass (MissionSight edge-lights mission) and the self-inspection record | airfield.light.out (alarm) | P1 | 3 | S-CAT, MS-EVENTS | V |
| af-03 | Self-inspection records | daily Part 139 inspection results | compliance: Required daily; records kept 12 months. Held in Simplify i3. | yes (Simplify i3) | Read i3; no sensor | airfield.inspection.recorded (document)<br>airfield.discrepancy.opened (alarm) | P1 | 0 | CFR-139.327, RFP | S |
| af-04 | FOD found | object, place, time | safety, compliance: FOD guidance updated in AC 150/5210-24A; CertAlert 24-03. | partial (self-inspection records) | Records first; drone sweeps; fixed FOD radar (AC 150/5220-24) only after a business case | airfield.fod.found (alarm)<br>airfield.fod.removed (state) | P1 | 0 | FAA-5210-24A, FAA-CA-24-03, FAA-5220-24 | S |
| af-05 | Standing water and ponding | water on pavement after rain | safety: Florida rain; braking. Pooling is better found by survey than by one embedded sensor. | no (nothing) | Lidar or drone survey after heavy rain; a Vaisala DRS511 class sensor only at a known spot | airfield.surface.water_film (reading)<br>airfield.ponding.found (alarm) | P1 | 3 | S-CAT | V |
| af-06 | Pavement condition | distress, PCI | cost, safety: FDOT inspects on about a three-year cycle; AC 150/5380-6C covers distress and repair. | partial (FDOT's pavement reports) | Drone or lidar survey between FDOT cycles | pavement.distress.found (document)<br>pavement.pci.updated (reading) | P2 | 3 | S-CAT, FAA-5380-6C | V |
| af-07 | Wildlife sightings and strikes | species, count, place; strikes | safety, compliance: SFB runs wildlife projects (Phase 1 on Twy B/B7; Phase II at $2M). AC 150/5200-33C covers attractants. | partial (the wildlife log and strike reports) | A phone report into the Collector; avian radar only after a business case | airfield.wildlife.sighting (reading)<br>airfield.wildlife.strike (alarm) | P1 | 0 | FAA-5200-33C, S-LOCK | S |
| af-08 | Weather | wind, visibility, ceiling, precipitation | safety: Operations and ramp safety. SFB: asos row in the asset list. | yes (The ASOS on the field (public observations)) | Read the public observation feed | weather.observation (reading) | P1 | 0 | FAA-5220-16E, S-LIST | I |
| af-09 | Lightning near the ramp | strikes within a radius | safety: Ramp crews stop work when lightning is close. Florida has frequent storms. SFB: Ask who calls ramp closures today. | no (nothing named) | A commercial lightning data feed, no hardware | weather.lightning.within_radius (alarm)<br>weather.lightning.all_clear (state) | P1 | 1 | none | I |
| af-10 | Vehicle position on the movement area | position, speed, identity | safety: Runway incursions. VMAT funded (FAA grant Aug 2026). | no (the VMAT transponders, once fitted) | An ADS-B receiver the Authority owns | airfield.vehicle.position (reading)<br>airfield.vehicle.out_of_bounds (alarm) | P1 | 3 | S-CAT, FAA-5220-26 | V |
| af-11 | PAPI, beacon and wind cones | lit and aligned | safety, compliance: Visual aids on the self-inspection list. SFB: 28 PAPI and 5 wind cone rows. | partial (ALCMS for some; inspection for others) | Self-inspection record; drone night pass | airfield.visual_aid.fault (fault) | P1 | 1 | FAA-5340-26C, S-LIST | I |