Level 2 of 3 This component, complete on its own. Its files, sources and tests are the detail below. Open the detail
Brings in fire alarm, electrical, utility and energy management systems read-only through the registry, with licensed maintainers keeping control. Extends person-confirmed prediction from the phase 1 samples to every connected class, with intelligent visual analytics only where the Authority approves them and the model way chosen under DEP-15.
Dates
2029-02-01 to 2030-01-31
Requirements delivered
4
Work units
10
Needs
Needs P9
Work units (10)
Unit
Title
Dates
RFP
Needs
WU-10-1
Year 3 environments scaled to 20,000 points
2029-02-01 to 2030-01-31
B vi, C 7.4
WU-10-2
Year 3 order of work and gateway review
2029-02-01 to 2030-01-31
C 4.7, C 6.7
DEP-22
WU-10-3
Fire alarm read-only connector and exchange sheet
2029-02-01 to 2030-01-31
C 4.7, C 6.7
DEP-22
WU-10-4
Electrical and utility monitoring read-only connectors
2029-02-01 to 2030-01-31
C 4.7, C 6.7
DEP-22
WU-10-5
Energy management read-only connector
2029-02-01 to 2030-01-31
C 4.7, C 6.7
DEP-22
WU-10-6
Model way and data class gate per DEP-15
2029-02-01 to 2030-01-31
C 1.1, C 3.7, C 5.7
DEP-15, DEP-22
WU-10-7
Prediction across every connected class
2029-02-01 to 2030-01-31
C 1.1, C 3.7, C 5.7
DEP-15, DEP-22
WU-10-8
Model cards and prediction coverage by class
2029-02-01 to 2030-01-31
B vi, C 7.4
WU-10-9
Intelligent visual analytics behind the approval gate
2029-02-01 to 2030-01-31
C 1.1, C 3.7, C 5.7
DEP-15, DEP-22
WU-10-10
Year 3 support, sustainment and professional services
2029-02-01 to 2030-01-31
B v, C 7.4
DEP-22
WU-10-1: Year 3 environments scaled to 20,000 points
Depends on
none
Authority dependencies
none
Traces to
REQ-SFB-069
Functional requirements
4
WU-10-2: Year 3 order of work and gateway review
Record the Authority's DEP-22 order for year 3 and obtain the DEP-07 network and security review for any new outbound-only gateways before systems are brought in.
Depends on
none
Authority dependencies
DEP-22
Traces to
REQ-SFB-026
Functional requirements
4
WU-10-3: Fire alarm read-only connector and exchange sheet
Register the fire alarm system's points through the registry as read-only, with its approved exchange sheet and licensed maintainers keeping control.
Depends on
WU-10-1, WU-10-2
Authority dependencies
DEP-22
Traces to
REQ-SFB-026
Functional requirements
4
WU-10-4: Electrical and utility monitoring read-only connectors
Register the electrical and utility monitoring systems' points through the registry as read-only, each with an approved exchange sheet and a place in the object model.
Depends on
WU-10-1, WU-10-2
Authority dependencies
DEP-22
Traces to
REQ-SFB-026
Functional requirements
4
WU-10-5: Energy management read-only connector
Register the energy management system's points through the registry as read-only with its exchange sheet, joined to the assets and spaces it measures.
Depends on
WU-10-1, WU-10-2
Authority dependencies
DEP-22
Traces to
REQ-SFB-026
Functional requirements
0
WU-10-6: Model way and data class gate per DEP-15
Apply the Authority's chosen model way and the data classes each way may see as an enforced gate on every prediction and visual analytics call, with each call on the record.
Depends on
none
Authority dependencies
DEP-15, DEP-22
Traces to
REQ-SFB-036, REQ-SFB-037
Functional requirements
3
WU-10-7: Prediction across every connected class
Extend the person-confirmed anomaly-to-work-request prediction from the phase 1 samples to every connected asset class, each prediction naming its inputs and waiting for a person.
Depends on
WU-10-6, WU-10-3, WU-10-4, WU-10-5
Authority dependencies
DEP-15, DEP-22
Traces to
REQ-SFB-036, REQ-SFB-037
Functional requirements
4
WU-10-8: Model cards and prediction coverage by class
Publish a model card per class and a coverage view showing which assets are predicted and which gaps remain for the year 4 retrofit survey.
Depends on
WU-10-7
Authority dependencies
none
Traces to
REQ-SFB-069
Functional requirements
3
WU-10-9: Intelligent visual analytics behind the approval gate
Enable intelligent visual analytics only for classes the Authority approves, within the Genetec evaluation limits on what is shown and to whom.
Depends on
WU-10-6
Authority dependencies
DEP-15, DEP-22
Traces to
REQ-SFB-036, REQ-SFB-037
Functional requirements
4
WU-10-10: Year 3 support, sustainment and professional services
Deliver year 3 support, upgrades and professional services against the contract terms and keep the support log and sustainment record that carry into years 4 and 5.
Depends on
WU-10-1
Authority dependencies
DEP-22
Traces to
REQ-SFB-053, REQ-SFB-054
Functional requirements
3
Requirements delivered (4)
Id
Requirement
Acceptance
Evidence
REQ-IMP-062
the environments stay healthy and the bill tracks the model.
the monthly cost and health report.
REQ-IMP-063
Further terminal systems read where the Authority approves: fire alarm, electrical and utility monitoring, and energy management, read only, with licensed maintainers keeping control.
each system joins read-only through the registry.
the exchange sheets.
REQ-IMP-064
Prediction across every connected class, with intelligent visual analytics where the Authority approves them.
each prediction names its inputs and waits for a person.
the model cards.
REQ-IMP-065
Support, sustainment and professional services for year 3.